CVE-2021-26727
Multiple command injections and stack-based buffer overflows vulnerabilities in the SubNet_handler_func function of spx_restservice allow an attacker to execute arbitrary code with the same privileges as the server user (root).
An un-authenticated remote attacker would be able to execute arbitrary code with root privileges on the BMC and, potentially, abuse it to also compromise the managed host.
October 21, 2022
The vulnerability affects: Lanner Inc IAC-AST2500A standard firmware version 1.10.0
CVE-2021-26727
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
10.0
Updated BMC firmware versions that fix the issue are available from Lanner technical support
Andrea Palanca of Nozomi Networks
Curated and maintained by Nozomi Networks Labs, the Threat Intelligence™ service provides threat and vulnerability updates to Guardian, making it easy for IT/OT professionals to stay on top of current OT and IoT risks.
Learn more“Threat actors love finding new ways to attack critical infrastructure. We love finding new ways to detect their malware before damage occurs.”
TRITON is the first known cyberattack that directly interacted with a Safety Instrumented System (SIS). Labs reverse engineered the TriStation suite of software and delivered a report and two free tools for security researchers. This research was presented at Black Hat USA 2018.
The Labs team reverse engineered the GreyEnergy malicious document (maldoc) that leads to the installation of the malware (backdoor) on a victim’s network. Project outcomes include a report, multiple blogs and two free tools for security researchers.
IEC Working Group 15 (WG15) is developing technology standards for secure-by-design power systems. Labs contributes to the standards and has demonstrated how they can be used to identify hard-to-detect cyberattacks. Research from this effort was presented at Black Hat USA 2019.