Command Injection

CVE-2024-50362

Summary

A CWE-78 “Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')” was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "connection_profile_apply" API which are not properly sanitized before being concatenated to OS level commands.

Impact

The vulnerability can be exploited by authenticated users to gain full, unrestricted root access to the wireless access point.

Issue Date

November 26, 2025

Affects

The following products and firmware versions are affected: EKI-6333AC-2G ≤ v1.6.3 EKI-6333AC-2GD ≤ v1.6.3 EKI-6333AC-1GPO ≤ v1.2.1

CVE Name

CVE-2024-50362

CVSS Details

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

CVSS Score

7.2

Solution

Update affected products to the following firmware versions released by Advantech: - EKI-6333AC-2G: v1.6.5 - EKI-6333AC-2GD: v1.6.5 - EKI-6333AC-1GPO: v1.2.2

Mitigations

Acknowledgements

Diego Zaffaroni of Nozomi Networks

Threat Intelligence

Curated and maintained by Nozomi Networks Labs, the Threat Intelligence™ service provides threat and vulnerability updates to Guardian, making it easy for IT/OT professionals to stay on top of current OT and IoT risks.

Learn more
Threat Intel screenshot
Nozomi Logo circle

“Threat actors love finding new ways to attack critical infrastructure. We love finding new ways to detect their malware before damage occurs.”

Research Projects

TRITON

TRITON is the first known cyberattack that directly interacted with a Safety Instrumented System (SIS). Labs reverse engineered the TriStation suite of software and delivered a report and two free tools for security researchers. This research was presented at Black Hat USA 2018.

GreyEnergy

The Labs team reverse engineered the GreyEnergy malicious document (maldoc) that leads to the installation of the malware (backdoor) on a victim’s network. Project outcomes include a report, multiple blogs and two free tools for security researchers.

IEC 62351

IEC Working Group 15 (WG15) is developing technology standards for secure-by-design power systems. Labs contributes to the standards and has demonstrated how they can be used to identify hard-to-detect cyberattacks. Research from this effort was presented at Black Hat USA 2019.

See all

Take the next step.

Discover how easy it is to identify and respond to cyber threats by automating your IoT and OT asset discovery, inventory, and management.